| ====== Registers ====== | ====== Registers ====== | ||
| + | |||
| + | Registers are a key element of AVR microcontrollers. There are various types of registers, including general-purpose, | ||
| + | |||
| + | AVR CPU General Purpose Working Registers (R0-R31) | ||
| + | |||
| + | **R0-R15: | ||
| + | Basic general-purpose registers are used for various arithmetic and logical operations. | ||
| + | |||
| + | **R16-R31: | ||
| + | General-purpose registers that can be used with immediate | ||
| + | |||
| + | Comparison Table: AVR Registers R0–R15 vs. R16–R31 | ||
| + | |||
| + | ^ Feature | ||
| + | | Instruction compatibility | ||
| + | | Opcode encoding | ||
| + | | Typical compiler usage | Less preferred; used for temporary or special roles | ||
| + | | Special-purpose roles | ||
| + | | Pointer support | ||
| + | | Efficiency | ||
| + | | Multiplication involvement | ||
| + | | Suitability in ASM | Limited; avoid with immediates; R0/R1 have special rules | Recommended for general ALU operations | ||
| + | | GCC policy | ||
| + | |||
| + | <figure avr_registers> | ||
| + | {{en: | ||
| + | < | ||
| + | </ | ||
| + | |||
| + | |||
| + | **The X-register, Y-register, and Z-register: | ||
| + | address pointers for indirect addressing | ||
| + | R26-R31: These registers serve as 16-bit address pointers for indirect addressing of the data space. They are defined as X, Y, and Z registers. | ||
| + | |||
| + | <figure avr_registers> | ||
| + | {{en: | ||
| + | < | ||
| + | </ | ||
| + | **Other registers: | ||
| + | |||
| + | RAMPX, RAMPY, RAMPZ: Registers concatenated with the X-, Y-, and Z-registers, | ||
| + | |||
| + | RAMPD: Register concatenated with the Z-register, enabling direct addressing of the whole data space on MCUs with more than 64 KB data space. | ||
| + | |||
| + | EIND: Register concatenated with the Z-register, enabling indirect jump and call to the entire program space on MCUs with more than 64K words (128 KB) of program space. | ||
| + | |||
| + | <table Register properties> | ||
| + | < | ||
| + | ^ Register | ||
| + | | RAMPX | ||
| + | | RAMPY | ||
| + | | RAMPZ | ||
| + | | RAMPD | ||
| + | | EIND | Extends program addressing | ||
| + | </ | ||
| + | |||
| + | All of the registers RAMPX, RAMPY, RAMPZ, RAMPD, and EIND are located in the extended I/O space of AVR microcontrollers. This area typically occupies addresses 0x3B–0x3F, | ||
| + | |||
| + | |||
| + | |||